Explosives
Technical documentation of the condensed-phase explosives model (mining and construction magazines, fireworks, powder and ammonium nitrate stores) — TNT equivalent, surface-burst curve and quantity-distance safety distances.
1. Physical phenomenon#
This model evaluates the accidental detonation of an explosives inventory in storage or handling: a mine or construction-site magazine, a fireworks workshop or store, a powder store or an ammonium nitrate store. The detonation releases the explosive's chemical energy in microseconds and produces:
- a blast wave travelling out from the charge, and
- projections of packaging, structure and soil (not modelled in this version).
The inventory is classified by UN Class 1 hazard division, which is how safety-distance standards classify it:
| Division | Behaviour in an accident | Examples | In TekRisk |
|---|---|---|---|
| 1.1 | Mass explosion | Cartridged dynamites and emulsions, detonating cord, boosters, unpackaged detonators, black powder, 1.1G display fireworks | Calculated |
| 1.5 | Very insensitive, but with mass explosion | Bulk blasting agents | Calculated as 1.1 |
| 1.3 | Fire with intense radiation | 1.3G display fireworks, propellant powders | Later phase |
| 1.4 | Minor hazard | Consumer fireworks, packaged detonators | Later phase |
| 5.1 | Oxidizer that can detonate | Technical or fertilizer-grade ammonium nitrate (UN1942, UN2067 with more than 80 % AN) | Calculated, with its own distance criterion |
Ammonium nitrate is not a Class 1 explosive, but a contaminated or burning store can detonate: Beirut (2020, about 2,750 t) and West, Texas (2013, about 30 t). It is modelled on its own source type, «Ammonium nitrate store», or by choosing its family at a magazine.
2. Calculation sequence#
flowchart TD A["Inventory<br/>family, UN division, NEQ"] --> B["TNT equivalent<br/>W = NEQ × f × η"] B --> C["Scaled distance<br/>z = r / W^⅓"] C --> D["TNT surface-burst curve<br/>(CCPS Table 2.17)"] D --> E["Zones, receivers, probit,<br/>fatalities, IR and F-N"] A --> F["Quantity-distance on the NEQ<br/>DoD, Canada, Australia (AN) or own K"] F --> G["Regulatory rings<br/>and compliance by receiver"]
3. Equations#
3.1 TNT equivalent#
is the net explosive quantity (NEQ) in kg: the explosive substance without packaging, adding all packages that can detonate together. is the mass of TNT, per kilogram of the explosive, that gives the same peak overpressure at the same distance. The overpressure basis is used because the lethality probits depend on overpressure. is the yield, the share of the mass that detonates: 1 for Class 1 explosives and 75 % by default for ammonium nitrate (see 3.3). An own yield requires its reference.
Each family has its own default factor, following the rule of DESR 6055.09 (V5.E3.1.3.1): TNT equivalencies greater than 1 may be applied; equivalencies less than 1 require supporting data. Families with a measured equivalence above 1 use it; the rest use 1, even when the literature reports less, because going below 1 needs data for the specific product.
| Family | Evidence | |
|---|---|---|
| Nitroglycerine dynamites and gelatines | 1.30 | Blasting gelatine in free air (Formby, HSL, 1995) |
| Detonating cord | 1.27 | PETN, pressure and impulse (UFC 3-340-02, Table 2-1) |
| Boosters | 1.11 | 50/50 pentolite hemispheres on the ground (Swisdak, NSWC) |
| Cartridged emulsions and water gels | 1.0 | Measured 0.69 (Formby, HSL, 1995) |
| Unpackaged detonators | 1.0 | No published value; the metal shell absorbs energy |
| Black powder | 1.0 | Measured 0.40 or less with 400 kg on the surface (Iida et al., 1997) |
| Display fireworks 1.1G | 1.0 | Flash powder 0.4 to 1.3 |
| Bulk blasting agents 1.5 | 1.0 | ANFO 0.82 (90–1,800 kg) to 0.94 (20–100 t); emulsions about 0.7 |
The former «Packaged high explosives» family grouped dynamites and emulsions, which have different factors. It has been retired: a scenario that still uses it cannot be calculated until one of the two families is chosen.
With product data (data sheet or airblast test) you can enter your own factor with its reference. Because distances scale with , an error of 25 % in the factor moves distances by only about 7 % (Cooper, 1994).
3.2 Blast wave#
Hopkinson-Cranz scaling:
Overpressure, impulse, positive-phase duration and arrival time come from the Kingery-Bulmash surface-burst curve, in the Lees polynomial fit (CCPS Table 2.17), the same one used by the VCE and physical explosion models. It is the geometry of a charge resting on the ground. Impulse and times scale with . Beyond m/kg^⅓ the overpressure is extended log-log and the zone is flagged as extrapolated. Below m/kg^⅓ the curve is no longer valid and is evaluated at that radius.
The curve reproduces the overpressures that the standards associate with each scaled distance: 8.1 kPa at K40 (DESR: 8.3 kPa) and 6.1 kPa at K50 (DESR: 6.2 kPa), and within −3 % to +14 % of the NRCan / NATO table between 5 and 180 kPa.
3.3 Ammonium nitrate#
| Parameter | Value | Source |
|---|---|---|
| 0.25 | Western Australia code (DMIRS, 2021), taken from the International Fertiliser Society (2006); measurements give 0.20 to 0.33 depending on distance (FFI, 2022) | |
| 75 % | FFI recommendation for stores; minimum acceptable 50 % (FFI, 2022) |
Ammonium nitrate is not a DESR explosive, so its «at least 1» rule does not apply: the 0.25 is backed by measurements.
With and , the curve gives 5.3, 7.0, 14.0 and 21.1 kPa at the code distances, against the 5.5, 7, 14 and 21 kPa the code associates with them.
4. Quantity-distance#
Distances for an aboveground magazine with division 1.1 or 1.5 contents, calculated on the NEQ, with three criteria (4.1 to 4.3). Ammonium nitrate has its own (4.4), and bulk nitrate next to a magazine adds mass to the NEQ (4.5).
4.1 DoD DESR 6055.09#
Inhabited building distance (IBD), Table V3.E3.T1, «Other PES» column:
| NEQ (kg) | IBD | Governed by |
|---|---|---|
| ≤ 14.1 | 61 m | Fragments (Table V3.E3.T2, structure) |
| 14.1 – 204.1 | m | Fragments |
| 204.1 – 13,837 | 381 m | Fragments and debris |
| 13,837 – 45,359 | (K40) | Blast wave |
| 45,359 – 113,398 | Blast wave | |
| > 113,398 | (K50), at least 960.4 m | Blast wave |
The DESR sets the fragment distance up to 13,608 kg and K40 from there, but K40 only reaches 381 m at 13,837 kg; in between TekRisk keeps 381 m so that more explosive never gives a shorter distance (the DESR table does not drop either: 1,250 ft for 30,000 lb). Likewise, the K50 range starts at the 960.4 m where the previous one ends. Public traffic route distance = 60 % of the IBD. Shorter distances require a DDESB-approved analysis or test.
4.2 Canada RP-05-04 (NATO AASTP-1 / IATG basis)#
Category PE 1, Table 9.2 values: inhabited building = D7 ( below 4,500 kg, above, minimum 270 m) and medium-traffic public route = D5 ( or , minimum 180 m). If the NEQ falls between two rows of the table, the larger one applies. Built-up areas with 20 or more people require at least 400 m: TekRisk applies it to receivers with that population.
4.3 Own K factors#
with the K of a national or authority table and its reference. Blast wave only.
The results compare each receiver's distance with the required one and flag it «Complies» or «Fails». A polygon receiver that contains the charge counts as 0 m, not as the distance to its edge.
4.4 Ammonium nitrate store (Western Australia)#
DMIRS, Safe storage of solid ammonium nitrate – code of practice, 4th ed. (2021), Table 4.1 and its notes. is the mass of the largest stack, and the distance is a cube-root law on the code's TNT mass:
| Protected place | (m/kg^⅓) | Code overpressure |
|---|---|---|
| Vulnerable facilities and critical infrastructure | 22.2 | 5.5 kPa |
| Dwellings, hotels and accommodation | 17.8 | 7 kPa |
| Commercial development | 10.4 | 14 kPa |
| Industrial buildings | 7.8 | 21 kPa |
Below 10 t, 15 m is enough for commercial and industrial buildings. The code table rounds to 10 m; TekRisk gives the formula value. The scenario yield does not change these distances.
4.5 Bulk ammonium nitrate next to a magazine#
NRCan RP-05-04, §9.1 and Table 9.3 (the Australian code, §4.2, says the same): if the nitrate is closer to the magazine than the table separation, half of its mass is added to the NEQ before applying the distances. The separation depends on the magazine NEQ and on whether there is a barricade with the table's minimum thickness. Example from the standard: 30 t of nitrate next to a 20 t magazine require 40 m without a barricade, or 6.6 m with a 0.87 m barricade; if they are not met, the NEQ becomes 35,000 kg.
The addition to the NEQ for the distances applies only with the Canadian criterion (4.2), the standard that contains this rule; with DoD (4.1) or custom K factors (4.3) the distances are computed on the magazine NEQ, without mixing standards.
TekRisk also adds that half to with factor 1, with any criterion. This is a conservative assumption: the standard only requires it for the distances.
5. Limitations#
- The wave is assumed hemispherical and symmetric: barricades, earth mounds and magazine confinement are not modelled.
- Fragments are not modelled as a consequence; they only enter the regulatory distances.
- Propagation between magazines (sympathetic detonation) is not modelled.
- Divisions 1.3 and 1.4 (fire) are not calculated yet.
- For ammonium nitrate, the preceding fire, the nitrous gases and the contamination that makes it more sensitive are not modelled; the yield is an assumption.
- A single-figure TNT equivalence is an approximation: the actual ratio depends on distance and differs for pressure and impulse.
- The lethality probits depend on overpressure only. For short-duration pulses from condensed charges this is conservative.
6. Inputs and outputs#
| Input | Tab | Note |
|---|---|---|
| Product family | Product | Sets the UN division, compatibility group and default factor. |
| Own TNT factor | Product | Optional; requires its reference. Below 1 only with product data. |
| Own yield | Product | Optional, in %; requires its reference. Empty = 75 % for ammonium nitrate and 100 % otherwise. |
| Net explosive quantity | Inventory | In kg, ton or lb. |
| Quantity-distance criterion | Distances | DoD DESR 6055.09, Canada RP-05-04 or own K factors with reference; for ammonium nitrate, the Western Australia code or own K factors. |
| Nearby ammonium nitrate | Distances | Class 1 explosives only: mass, separation and whether there is a barricade with the Table 9.3 thickness. |
| Frequency | Model | For IR and F-N. |
| Population density and probit | Vulnerability | Overpressure lethality (Eisenberg or Hurst). |
| Overpressure zones | Zones | Thresholds with their unit. |
Outputs: TNT equivalent; distance, impulse, duration and arrival time per zone; quantity-distance distances with what governs each one and the overpressure there; compliance by receiver; receiver effects (lethality, eardrum, structures, glass and domino effect on equipment) and fatalities by rings.
7. References#
- UN (2023). Recommendations on the Transport of Dangerous Goods, Model Regulations, ch. 2.1 «Class 1 — Explosives».
- DDESB (2024). DESR 6055.09, Defense Explosives Safety Regulation, Edition 1, Change 1. Tables V3.E3.T1 and V3.E3.T2; V5.E3.1.3.1.
- Natural Resources Canada (2025). RP-05-04 Separation Distances for Explosives, Tables 9.1, 9.2 and 9.3; §9.1.
- Department of Mines, Industry Regulation and Safety (2021). Safe storage of solid ammonium nitrate – code of practice, 4th ed. Government of Western Australia. Table 4.1 and §4.2.
- Kristensen, T.E. & Osnes, A.N. (2022). Safe storage of ammonium nitrate products – scientific framework for government regulations. FFI-rapport 22/02158, Norwegian Defence Research Establishment.
- NATO AASTP-1. Manual of NATO Safety Principles for the Storage of Military Ammunition and Explosives.
- Kingery, C.N. & Bulmash, G. (1984). Airblast Parameters from TNT Spherical Air Burst and Hemispherical Surface Burst, ARBRL-TR-02555.
- CCPS (2000). Guidelines for Chemical Process Quantitative Risk Analysis, 2nd ed., Table 2.17. AIChE.
- Lees, F.P. (1996). Loss Prevention in the Process Industries, 2nd ed.
- Formby, S.A. (1995). Quantification of the air blast characteristics of commercial explosives. IChemE Symposium Series 139, 147–160.
- US DoD (2008). UFC 3-340-02 Structures to Resist the Effects of Accidental Explosions, Table 2-1.
- Swisdak, M.M. TNT Equivalency of Pentolite Hemispheres. NSWC (DTIC ADA123340).
- Iida, M. et al. (1997). Blast characteristics of black powder. Kayaku Gakkaishi 58(6).
- Cooper, P.W. (1994). Comments on TNT Equivalence. Sandia National Laboratories, SAND94-1614C.
- Fuchs, B.E., Covino, J. & Baker, E. (2018). A Critical Review of TNT Equivalency. International Explosives Safety Symposium.